|
UPT. PERPUSTAKAAN
Universitas Esa Unggul
Kampus Emas UEU - Jakarta Barat
|
Phone |
: |
021-5674223, ext 282 |
Fax |
: |
|
E-mail |
: |
[email protected] |
Website |
: |
http://library.esaunggul.ac.id
|
Support (Customer Service) :
|
[email protected] |
|
|
Welcome..guys!
|
Have a problem with your access?
Please, contact our technical support below:
|
LIVE SUPPORT
Astrid Chrisafi
|
! ATTENTION !
To facilitate the activation process, please fill out the member application form correctly and completely
Registration activation of our members will process up to max 24 hours (confirm by email). Please wait patiently
Still Confuse?
Please read our User Guide
|
|
UEU » Undergraduate Theses » Keperawatan Posted by [email protected] at 15/07/2019 11:54:21 • 2140 Views
EFEKTIFITAS PENGHISAPAN LENDIR ENDOTRAKEAL TUBE (ETT) MENGGUNAKAN TEKNIK OPEN SUCTION DAN CLOSED SUCTION TERHADAP KADAR SATURASI OKSIGEN PADA PASIEN DI RUANG ICU RS PANTAI INDAH KAPUK TAHUN 2018Created by :
NICHOLAS DARMAWAN ( 20160303083 )
Subject: | SATURASI OKSIGEN ENDOTRACHEAL TUBE SUCTION | Alt. Subject : | OXYGEN SATURATION ENDOTRACHEAL TUBE SUCTION | Keyword: | saturasi oksigen open suction dan close suction endotracheal tube (ETT) |
Description:
Salah satu peralatan standar minimal di Intensive Care Unit (ICU) adalah ventilator yang berfungsi untuk membantu pasien bernafas melalui Endotracheal Tube (ETT). Penghisapan lendir (suction) merupakan salah satu tindakan untuk membersihkan jalan nafas pasien khususnya pasien yang menggunakan ventilator. Penelitian ini bertujuan untuk mengetahui efektifitas penghisapan lendir ETT menggunakan teknik open suction dan closed suction terhadap kadar saturasi oksigen. Metode yang digunakan Pra Eksperimen. Besar sample 34 responden, terdiri dari kelompok close suction dan kelompok open suction yang diambil dengan teknik accidental sampling. Hasil uji T-test paired didapatkan nilai saturasi oksigen sebelum dan sesudah dilakukan tindakan suction pada pasien dengan ETT kelompok close suction dan open suction p-value <0,05 (0,000). didapatkan data saturasi sebelum dilakukan tindakan close suction dengan rata-rata 90,76%. Sedangkan saturasi setelah tindakan close suction meningkat dengan rata-rata 96,70%. Kesimpulan bahwa tindakan penghisapan lendir (suction ) dengan metode Close Suction System (CSS) lebih efektif dalam menaikkan nilai saturasi oksigen dari metode Open Suction System (OSS). Disarankan khususnya profesi keperawatan agar dijadikan pedoman dalam melakukan tindakan penghisapan lendir (suction), khusunya menggunakan teknik Close Suction System sangat dianjurkan dalam melakukan penghisapan lendir (Suction). Hal ini sangat efektif dalam meningkatkan nilai saturasi oksigen pada pasien yang terpasang alat bantu nafas (ventilator).
Contributor | : |
- Yayah Karyanah, B.Sc., S.Sos., M.M
| Date Create | : | 15/07/2019 | Type | : | Text | Format | : | pdf | Language | : | Indonesian | Identifier | : | UEU-Undergraduate-20160303083 | Collection ID | : | 20160303083 |
Source : Undergraduate Theses of Nursing
Relation Collection: Fakultas Ilmu Ilmu kesehatan
Coverage : Civitas Akademika Universitas Esa Unggul
Rights : @Perpustakaan Universitas Esa Unggul 2019
Publication URL : https://digilib.esaunggul.ac.id/efektifitas-penghisapan-lendir-endotrakeal-tube-ett-menggunakan-teknik-open-suction-dan-closed-suction-terhadap-kadar-saturasi-oksigen-pada-pasien-di-ruang-icu--rs-pantai-indah-kapuk-tahun-2018-13141.html
[ Free Download - Free for All ]
- UEU-Undergraduate-13141-COVER.Image.Marked.pdf - 437 KB
- UEU-Undergraduate-13141-HALAMAN PENGESAHAN.Image.Marked.pdf - 585 KB
- UEU-Undergraduate-13141-HALAMAN PERNYATAAN KEASLIAN.Image.Marked.pdf - 472 KB
- UEU-Undergraduate-13141-LEMBAR PERSETUJUAN.Image.Marked.pdf - 551 KB
- UEU-Undergraduate-13141-PERSETUJUAN PUBLIKASI.Image.Marked.pdf - 613 KB
- UEU-Undergraduate-13141-ABSTRAK.Image.Marked.pdf - 426 KB
- UEU-Undergraduate-13141-KATA PENGANTAR.Image.Marked.pdf - 768 KB
- UEU-Undergraduate-13141-DAFTAR ISI dkk.Image.Marked.pdf - 435 KB
- UEU-Undergraduate-13141-DAFTAR PUSTAKA.Image.Marked.pdf - 432 KB
- UEU-Undergraduate-13141-LAMPIRAN.Image.Marked.pdf - 902 KB
- UEU-Undergraduate-13141-BAB1.Image.Marked.pdf - 741 KB
- UEU-Undergraduate-13141-BAB2.Image.Marked.pdf - 558 KB
[ FullText Content - Please, register first ]
1. UEU-Undergraduate-13141-BAB3.Image.Marked.pdf - 458 KB 2. UEU-Undergraduate-13141-BAB4.Image.Marked.pdf - 535 KB 3. UEU-Undergraduate-13141-BAB5.Image.Marked.pdf - 358 KB 4. UEU-Undergraduate-13141-BAB6.Image.Marked.pdf - 418 KB
10 Similar Document...
No similar subject found !
10 Related Document...
|
POLLINGBagaimana pendapat Anda tentang repository kami ?
Visitors Today : 1
Total Visitor : 1970121
Hits Today : 118914
Total Hits : 158200539
Visitors Online: 1
Calculated since 16 May 2012
You are connected from 172.17.121.29 using Mozilla/5.0 AppleWebKit/537.36 (KHTML, like Gecko; compatible; ClaudeBot/1.0; [email protected])
|